SiUS041111 Outdoor Unit: 09/12 Class
Removal Procedure 175
2. Remove the thermistors.
Pay attention so as not to lose
the fixture for thermistor.
When reassembling, do not
insert the thermistor up to the
dent of fixture.
1
Release the discharge
pipe thermistor.
2
Release the outdoor
heat exchanger
thermistor.
3
Lift the hook with a flat
screwdriver, and
remove the electronic
components mounting
plate.
Step Procedure Points
Discharge pipe thermistor
(R11765)
Dent
Fixture
(R11740)
(R11766)
Outdoor heat
exchanger thermistor
Electronic components mounting plate
(R11767)