SiBE041102_A Indoor Unit
Removal Procedure 103
5
Loosen the screws of
the terminal board and
disconnect the
connecting wires.
Connecting wires
black (1) ----- power supply
white (2) ----- power supply
red (3) ----- transmission
yellow / green ( )
----- earth
6
Pull out the indoor heat
exchanger thermistor.
Take care not to lose the clip
of thermistor.
2. Remove the electrical box.
1
Remove the screw and
disconnect the earth
wire.
Step Procedure Points
Terminal board
(R11639)
Connecting
wires
(R12045)
Indoor heat exchanger thermistor
Clip
(R11268)
Thermistor
Screw
(R12046)
Earth
wire