Outdoor Unit SiBE041102_A
118 Removal Procedure
2. Outdoor Unit
2.1 Removal of Outer Panels
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
1. Appearance features
Take care not to cut your
finger by the fins of the
outdoor heat exchanger.
2. Remove the panels.
The stop valve cover is
united with the shield plate.
When reassembling, make
sure to fit the 3 hooks.
1
Remove the screw of
the stop valve cover.
Pull down the stop
valve cover and remove
it.
(R10707)
(R14485)
(R10709)
Stop valve
cover
(R14606)
Shield plate
Hook