Loading...
Outdoor Unit SiBE041102_A
132 Removal Procedure
2.5 Removal of Four Way Valve
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
1. Remove the peripheries.
1
Remove the screw and
remove the four way
valve coil.
2
Remove the terminal
cover.
3
Disconnect the
terminals of the
compressor.
4
Remove the overload
protector.
(R14527)
Four way valve coil
(R14528)
Terminal cover
(R14529)
U(red)
V(yellow) W(blue)
Overload
protector