23
Performance Data
Performance Data
Model: 2MX45BGXV1
Cooling Mode
Combination of indoor unit *
Each capacity (kW) Total capacity (kW) Total input (W) EER Total current (A)
A room B room Rated Max Rated Max Rated Rated Max
25
2.50 --- 2.50 3.00 620 820 4.03 2.90 3.80
35
3.50 --- 3.50 4.00 1080 1410 3.24 4.90 6.50
25 + 25
1.95 1.95 3.90 4.30 1030 1240 3.79 4.73 5.70
25 + 35
1.67 2.33 4.00 4.50 1050 1400 3.81 4.82 6.33
* Applicable for indoor size 15 using Ø9.52mm gas pipe
Heating Mode
Combination of indoor unit *
Each capacity (kW) Total capacity (kW) Total input (W) COP Total current (A)
A room B room Rated Max Rated Max Rated Rated Max
25
3.00 --- 3.00 3.70 850 1270 3.53 3.90 5.90
35
3.80 --- 3.80 4.40 1290 1730 2.95 5.90 7.90
25 + 25
2.18 2.18 4.36 4.70 1040 1200 4.20 4.73 5.40
25 + 35
1.94 2.46 4.40 5.10 1040 1450 4.23 4.76 6.50
* Applicable for indoor size 15 using Ø9.52mm gas pipe
Note : It is not recommended to connect the multi-split outdoor to single indoor only.
Model: 2MX50BGXV1
Cooling Mode
Combination of indoor unit *
Each capacity (kW) Total capacity (kW) Total input (W) EER Total current (A)
A room B room Rated Max Rated Max Rated Rated Max
25
2.50 --- 2.50 3.00 620 800 4.03 2.80 3.60
35
3.50 --- 3.50 3.70 980 1280 3.57 4.30 5.60
50
--- 5.00 5.00 5.80 1620 2100 3.09 7.10 9.20
25 + 25
2.50 2.50 5.00 5.80 1470 1910 3.40 6.40 8.40
25 + 35
2.13 2.97 5.10 6.00 1550 2140 3.29 6.90 9.40
25 + 50
1.75 3.45 5.20 6.00 1500 2070 3.47 6.60 9.10
35 + 35
2.55 2.55 5.10 6.00 1400 2140 3.64 6.20 9.40
35 + 50
2.22 3.18 5.40 6.20 1378 1720 3.92 6.10 7.60
* Applicable for indoor size 15 using Ø9.52mm gas pipe
Cooling Mode
Combination of indoor unit *
Each capacity (kW) Total capacity (kW) Total input (W) EER Total current (A)
A room B room Rated Max Rated Max Rated Rated Max
25 + 35
2.17 3.03 5.20 6.00 1550 2140 3.35 6.90 9.40
35 + 35
2.60 2.60 5.20 6.00 1400 2140 3.71 6.20 9.40
35 + 50
2.22 3.18 5.40 6.20 1378 1720 3.92 6.10 7.60
* Applicable for indoor size 15 using Ø12.70mm gas pipe
Note : It is not recommended to connect the multi-split outdoor to single indoor only.
Heating Mode
Combination of indoor unit *
Each capacity (kW) Total capacity (kW) Total input (W) COP Total current (A)
A room B room Rated Max Rated Max Rated Rated Max
25
3.00 --- 3.00 4.00 1000 1260 3.00 4.50 5.60
35
3.80 --- 3.80 4.50 1250 1680 3.04 5.60 7.50
50
--- 5.60 5.60 6.50 1850 2510 3.03 8.20 11.00
25 + 25
3.00 3.00 6.00 6.50 1570 2150 3.82 6.90 9.50
25 + 35
2.54 3.56 6.10 6.50 1640 2000 3.72 7.20 8.80
25 + 50
2.03 4.07 6.10 6.70 1600 1800 3.81 7.00 7.90
35 + 35
3.05 3.05 6.10 6.50 1600 1970 3.81 7.00 8.70
35 + 50
2.64 3.76 6.40 6.90 1492 1680 4.29 6.60 7.50
* Applicable for indoor size 15 using Ø9.52mm and Ø12.70mm gas pipe
Note : It is not recommended to connect the multi-split outdoor to single indoor only.