19
Application Information
* The gures shown in the table are for information purpose only. They should be checked and selected to comply with
the local/national codes of regulations. This is also subject to the type of installation and conductors used.
** The appropriate voltage range should be checked with label data on the unit.
Model FTXN25/35MV1 FTXN50MV1
Voltage Range**
220V - 240V / 1Ph / 50Hz+
Power supply cable size*
Number of core
mm
2
3.0
3
3.0
3
Interconnection cable size*
Number of core
mm
2
1.5
4
2.5
4
Recommended time delay fuse* A 25 25
Model FFQ25CXV1 FFQ35CXV1 FFQ50CXV1
Voltage Range**
220V - 240V / 1Ph / 50Hz+
Power supply cable size*
Number of conductors
mm
2
3.0
3
3.0
3
3.0
3
Interconnection cable size*
Number of conductors
mm
2
1.5
4
1.5
4
2.5
4
Recommended time delay fuse* A 25 25 25
Model FDMQ25C2XV1 FDMQ35CXV1 FDMQ50CXV1
Voltage Range**
220V - 240V / 1Ph / 50Hz+
Power supply cable size*
Number of conductors
mm
2
3.0
3
3.0
3
3.0
3
Interconnection cable size*
Number of conductors
mm
2
1.5
4
1.5
4
2.5
4
Recommended time delay fuse* A 25 25 25
Model FLQ35EXV1 FLQ50EXV1
Voltage Range**
220V - 240V / 1Ph / 50Hz+
Power supply cable size*
Number of conductors
mm
2
3.0
3
3.0
3
Interconnection cable size*
Number of conductors
mm
2
1.5
4
2.5
4
Recommended time delay fuse* A 25 25