EasyManua.ls Logo

Daikin FTXS30HVJU - Page 174

Daikin FTXS30HVJU
202 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Outdoor Unit SiUS04-924
Removal Procedure 167
4
Disconnect the
connector for fan motor
[S70] and release the 2
ferrite cores attached to
the electrical box with
clamp.
Fix the valves so that the
tension does not twist the
PCB assembly when
connecting the connectors.
5
The illustration shows
arrangement of the fan
motor lead wire.
6
Disconnect the
connectors of the front
side.
[S20]: electronic
expansion valve coil
[S80]: four-way valve
coil
[S90]: thermistors
(discharge pipe, outdoor
air,
heat exchanger)
Step Procedure Points
[S70]
Ferrite core
(R9620)
When reassembling, insert
the clamp into the small
hole.
Fixing position for ferrite
core of fan motor
(R9878)
Fixing position for
electronic expansion
valve coil
(R9621)
Fan motor lead wire
(R9622)
[ ]
[ ]
[ ]

Table of Contents