36
English
Operation stopped during COOL operation.
(OPERATION lamp ashes.)
When the outdoor temperature is lower than 10°C, do
not use COOL operation. If the operation is used when
the outdoor temperature is lower than 10°C, the protec-
tive function of the main unit works and this disables
the operation.
Turn the bleaker off and take all obstacles away. Then
turn it on again and try operating the air conditioner
with the remote controller. If the lamp still ashes, call
the service shop where you bought the air conditioner.
Hot air does not ow out soon after
the start of HEAT operation.
The air conditioner is warming up. You should wait for
1 to 4minutes. (The system is designed to start dis-
charging air only after it has reached a certain tem-
perature.)
The ON/OFF TIMER does not
operate according to the settings.
Check if the ON/OFF TIMER and the WEEKLY TIMER
are set to the same time.
Change or deactivate the settings in the WEEKLY
TIMER.
Page 21
Operation stopped suddenly.
(OPERATION lamp is on.)
For system protection, the air conditioner may stop
operating on a sudden large voltage uctuation. It
automatically resumes operation in about 3 minutes.
The indoor unit gives out odour.
This happens when smells of the room, furniture, or
cigarettes are absorbed into the unit and discharged
with the air ow.
(If this happens, we recommend you to have the indoor
unit washed by a technician. Consult the service shop
where you bought the air conditioner.)
Mist comes out of the indoor unit.
This happens when the air in the room is cooled into
mist by the cold air ow during COOL operation.
This is because the air in the room is cooled by the
heat exchanger and becomes mist during defrost
operation.
Remote controller does not work
properly.
No remote controller signals are displayed.
The remote controller sensitivity is low.
The display is low in contrast or blacked out.
The display runs out of control.
The batteries are dying and the remote controller is
malfunctioning. Replace all the batteries with new, size
AAA.LR03 (alkaline). For details, refer to set the batter-
ies of this manual.
Page 9
The outdoor fan rotates while the
air conditioner is not in operation.
After operation is stopped
The outdoor fan continues rotating for another
60 seconds for system protection.
While the air conditioner is not in operation
When the outdoor temperature is very high, the out-
door fan starts rotating for system protection.
01_EN_3P276869-1A.indb 3601_EN_3P276869-1A.indb 36 8/8/2012 4:18:35 PM8/8/2012 4:18:35 PM