16 | Unit installation
Installer and user reference guide
60
FXSA15~140A2VEB
VRV system air conditioner
4P599622-1 – 2020.05
f
b
e
d
c
a
a Water inlet
b Portable pump
c Water inlet cover
d Bucket (adding water through water inlet)
e Drain outlet for maintenance
f Refrigerant pipes
6 Turn OFF the power.
7 Disconnect the electrical wiring.
Remove the service cover.
Disconnect the power supply.
Disconnect the user interface.
Reattach the service cover.
When installation of the system is already completed
1 Start cooling operation (see the reference guide or the service manual of the
user interface).
2 Gradually pour approximately 1l of water through the water inlet, and check
for leaks (see "When installation of the system is not yet completed"[459]).