3 | Components
Service manual
125
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 โ 2021.01
a HAP LED
INFORMATION
Make sure the correct software is available on the PCB. If NOT, update using the
updater tool.
Does the HAP LED blink in regular
intervals (1๎second ON/1๎second OFF)?
Action
Yes Return to "Checking
procedures"๎
[4๎
123] of the main PCB
and continue with the next procedure.
No Replace the main PCB, see "Repair
procedures"๎
[4๎
131].
To check if the correct spare part is installed
Prerequisite: First perform all earlier main PCB checks, see "Checking
procedures"๎
[4๎
123].
1 Visit your local spare parts webbank.
2 Enter the model name of your unit and check if the installed spare part
number corresponds with the spare part number indicated in the webbank.
NOTICE
Also check that the correct spare part is installed for the capacity adapter.
Is the correct spare part for the PCB
installed?
Action
Yes Return to "Checking
procedures"๎
[4๎
123] of the main PCB
and continue with the next procedure.
No Replace the main PCB, see "Repair
procedures"๎
[4๎
131].
To check the wiring of the main PCB
Prerequisite: First perform all earlier main PCB checks, see "Checking
procedures"๎
[4๎
123].
Prerequisite: Stop the unit operation via the user interface.
1 Turn OFF the respective circuit breaker.
2 Check that all wires are properly connected and that all connectors are fully
pluggedโin.
3 Check that no connectors or wires are damaged.
4 Check that the wiring corresponds with the wiring diagram, see "6.2๎
Wiring
diagram"๎
[4๎
223].
INFORMATION
Correct the wiring as needed.
Is the problem solved? Action
Yes No further actions required.