EasyManua.ls Logo

Daikin Perfera FTXM71R - Page 243

Daikin Perfera FTXM71R
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 | Technical data
Service manual
243
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
RXM42~71R + ARXM50~71R
j
k
m
oq
r
a
b
c
de
f
g
p
h i
l
n
m
m
a Air thermistor R1T j Main PCB A1P
b Heat exchanger k Power supply terminal X1M
c Heat exchanger thermistor R2T l Muffler
d Liquid receiver m Expansion valve Y1E
e Stop valve with service port (gas) n Muffler with filter
f Stop valve (liquid) o Accumulator
g 4‑way valve Y1S p Compressor M1C
h Fan motor M1F q Discharge pipe thermistor R3T
i High pressure switch S1PH r Fan

Table of Contents

Related product manuals