3 | Components
Service manual
81
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
a Expansion valve motor
b Expansion valve motor harness
7 Cut all tie straps that fix the expansion valve motor harness.
8 Disconnect the expansion valve motor connector S20 from the main PCB.
9 Remove the expansion valve motor (and harness) from the unit.
10 To install the expansion valve motor, see "Repair procedures"[479].
To remove the expansion valve body
Prerequisite: Recuperate the refrigerant from the refrigerant circuit, see "Repair
procedures"[4209].
Prerequisite: If needed, remove any parts or insulation to create more space for
the removal.
1 Remove the expansion valve motor, see "Repair procedures"[479].
2 Remove the putty. Keep for re-use.
a Putty
b Expansion valve pipe
c Expansion valve body