EasyManua.ls Logo

Daikin R35CV1A - Removal of Horizontal Blades; Vertical Blades

Daikin R35CV1A
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Si01-406 FT50/60CV1A
Removal Procedure 153
2.3 Removal of Horizontal Blades / Vertical Blades
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the horizontal
blades.
1
Open the horizontal
blades.
It has no fixing screws inside
blades, though previous
models had.
2
Undo the left pivot of
the horizontal blades.
3
Bend the horizontal
blades slightly and
release the center
pivots.
Slide the horizontal
blades to the left and
release the right pivot.
Installation procedure
1. Since key pattern hook is
provided, rotate the blades
and fit it to the right pivot
first.
2. Fit the blades to the center
and left pivots.