61
TM-FLH--0515-C
Additional Charge
• The refrigerant charge has already charged into the outdoor unit. For the piping length of 7.5m,
additional refrigerant charge after vacuuming is not necessary.
• When the piping length is more than 7.5m, please use the table below (unit in gram).
For R22
For R410A
Indoor
FL15EV1L
FH15CBV1L
FH15CBV1M
Outdoor
R15CV1 R18CV1 R20CV1 R20CV1 R25CV1
15 16 16 16 38
FL25EV1L
FH25CBV1L
FH25CBV1M
Additional Charge of Refrigerant, g/m
Model
FL20EV1L
FH20CBV1L
FH20CBV1M
Indoor
FH50CBV1L
FH50CBV1M
FH61CBV1L
FH61CBV1M
Outdoor
R28CV1 R30CV1 R35DV1 R40DY1 R50DY1 R60DY1
40 50 50 50 50 102
FH30CBV1L
FH30CBV1M
FH40CBV1L
FH40CBV1M
Additional Charge of Refrigerant, g/m
Model
Indoor
FLN15EV1L
FLN15EV1M
FLN20EV1L
FLN20EV1M
FLN25EV1L
FLN25EV1M
FLN30EV1L
FLN30EV1M
Outdoor RN15FV1 RN20CV1 RN25CV1 RN28CV1
18 20 20 24
Additional Charge of Refrigerant, g/m
Model
Indoor
FLN50DV1L
FLN50DV1M
FHN62CV1L
FHN62CV1M
Outdoor RN35DV1 RN40DY1 RN50DY1 RN61DY1
45 45 45 21
Additional Charge of Refrigerant, g/m
Model
FLN40DV1L
FLN40DV1M
Example:
FL15EV1L & R15CV1 with 13m piping length, additional piping length is 5.5m. Thus,
Additional charge = 5.5[m] x 15[g/m]
= 82.5[g]