Daikin R42NUY2S - H9, J3, J5, J6, J7, J8 Thermistor System Abnormality

Daikin R42NUY2S
501 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting by Remote Controller Si20-701_B
237
3.45
H9
,
J3
,
J5
,
J6
,
J7
,
J8
Thermistor
System Abnormality
Remote Controller Display
H9
,
J3
,
J5
,
J6
,
J7
,
J8
Applicable Models
RZQ-K/H, RZQ(S)-B/C, RZR-KU/HU
Method of Error Detection
The error is detected according to the temperature
detected by each individual thermistor.
Error Decision Conditions
When thermistor is disconnected or short-circuited during
operation
Supposed Causes
Defective thermistor
Defective connection of connector
Defective outdoor unit control PCB