Loading...
System air conditioner
OPERATION MANUAL
MODEL
RXYQ72PYDN
RXYQ96PYDN
RXYQ120PYDN
RXYQ144PYDN
RXYQ168PYDN
RXYQ192PYDN
RXYQ216PYDN
RXYQ240PYDN
RXYQ72PTJU
RXYQ96PTJU
RXYQ120PTJU
RXYQ144PTJU
RXYQ168PTJU
RXYQ192PTJU
RXYQ216PTJU
RXYQ240PTJU
Read these instructions carefully before installation.
Keep this manual in a handy place for future reference.
This manual should be left with the equipment owner.
English
Français
Español
REYQ72PYDN
REYQ96PYDN
REYQ120PYDN
REYQ144PYDN
REYQ168PYDN
REYQ192PYDN
REYQ216PYDN
REYQ240PYDN
REYQ72PTJU
REYQ96PTJU
REYQ120PTJU
REYQ144PTJU
REYQ168PTJU
REYQ192PTJU
REYQ216PTJU
REYQ240PTJU
00_CV_3P215731-1D.fm Page 1 Wednesday, February 6, 2008 11:34 AM

Questions and Answers

  • A
    Alexa RichardsAug 8, 2025
    Why is my Daikin Air Conditioner not cooling or heating enough?
    • A
      andreawardAug 8, 2025
      If your Daikin Air Conditioner isn't cooling or heating sufficiently, several factors could be at play. First, ensure that neither the air inlet nor outlet of the indoor or outdoor unit is obstructed; remove any blockages to improve ventilation. Next, verify if the remote controller indicates it's time to clean the air filter. Also, review your temperature and fan speed settings on the remote. Other potential issues include open doors or windows, too many people in the room, excessive heat sources, direct sunlight, or an improper airflow angle. Check each of these elements to optimize performance.
  • W
    williamedwardsAug 15, 2025
    Why does my Daikin Air Conditioner stop soon after starting?
    • K
      Kevin NguyenAug 15, 2025
      If your Daikin Air Conditioner stops shortly after starting, examine the outdoor and indoor units to ensure that the air inlets and outlets are free from obstructions. Remove any obstacles to ensure proper ventilation. Also, check the remote controller display for an indication to clean the air filter and proceed to clean the air filter.
  • M
    Molly CombsAug 22, 2025
    What to do if my Daikin Air Conditioner system does not operate at all?
    • J
      Johnny BryanAug 22, 2025
      If your Daikin Air Conditioner system isn't starting, first check for a power failure and wait for the power to be restored. If there is no power failure, check if a fuse has blown and turn off the power supply. Another potential issue is a blown breaker.
  • J
    Justin LopezAug 30, 2025
    What to do if my Daikin Air Conditioner displays 'TEST' and a malfunction code?
    • A
      April CombsAug 30, 2025
      If the display on your Daikin Air Conditioner shows 'TEST', the unit number, and the TEST operation lamp are flashing, and a malfunction code appears, you should notify your Daikin dealer and report the malfunction code.

Summary

Safety Considerations

What to Do Before Operation

Remote Controller: Name and Function

On;Off Button and Operation Lamp

Details the function of the On/Off button and the red Operation lamp on the remote controller.

Remote Controller Display Indicators

Describes various indicators like temperature, mode, fan speed, and timer settings on the remote display.

Remote Controller Buttons and Switches

Details the function of buttons for timer, fan speed, operation mode, and switches for fan/cooling selection.

Specifications

Operation Range

Operation Procedure

Selecting Operation Modes

Guides on selecting cooling, heating, automatic, and fan-only modes for the system.

Adjusting System Settings

Explains how to adjust temperature, fan speed, and airflow direction for optimal comfort.

Heating Operation Details

Explains heating operation, including defrost and hot start features to prevent cold air.

Program Dry Operation

Describes the program dry function for dehumidification, noting its availability and limitations.

Adjusting Air Flow Direction

Guides on how to adjust the air flow direction for optimal comfort, including automatic and fixed settings.

Programming Start and Stop with Timer

Explains how to set the timer for automatic system start and stop, up to 72 hours.

Setting the Master Remote Controller

Details how to designate a master controller in multi-unit systems and manage operation modes.

Optimum Operation

Precautions for Group;Dual Remote Control Systems

Outlines precautions for group or dual remote control systems and how to configure them.

Seasonal Maintenance

Beginning of Season Maintenance

Covers checks for blocked vents and exterior cleaning at the start of the operating season.

End of Season Maintenance

Details procedures for preparing the unit at the end of the season, including fan operation and power shutdown.

Troubleshooting Common Symptoms

System Not Operating or Stopping Intermittently

Addresses issues where the air conditioner does not start, stops intermittently, or cannot change modes.

Fan and Cooling;Heating Issues

Troubleshoots fan speed/direction discrepancies and scenarios where cooling/heating fails.

Unit Noises and Other Issues

Explains white mist, unit noises, dust emission, odors, and fan rotation issues.

Display Indicators and Unit States

Explains specific display messages like '80', compressor/fan behavior, and unit warmth after stopping.

Insufficient Cooling and Program Dry

Addresses insufficient cooling and explains the limitations of Program Dry operation.

Troubleshooting Specific Malfunctions

System Not Operating or Stopping

Provides steps for diagnosing systems that do not operate at all or stop shortly after starting.

Insufficient Cooling or Heating Performance

Guides on diagnosing and resolving issues with insufficient cooling or heating performance.

After-Sales Service and Warranty

Service and Repair Information

Details how to contact dealers for service, warranty claims, and minimum parts availability.

Maintenance and Inspection Recommendations

Outlines recommendations for professional maintenance and inspection cycles for various unit parts.

Unit Moving and Disposal

Provides instructions for moving the unit and for the environmentally safe disposal of refrigerants.

Contacting for Service

Guidance on who to contact for after-sales service, warranty issues, and repair needs.

Daikin REYQ96PYDN Specifications

General IconGeneral
CategoryHeat Pump
RefrigerantR-410A
Cooling Capacity27.0 kW
Heating Capacity96, 000 BTU/h
Weight (Outdoor Unit)172 kg
Operating Temperature (Cooling)-5 to 46 °C
Operating Temperature (Heating)-13°F to 75°F
ModelDaikin REYQ96PYDN