Installer reference guide
R32 split series
RXF20E5V1B
RXF25E5V1B
RXF35E5V1B
RXF42E5V1B
ARXF20E5V1B
ARXF25E5V1B
ARXF35E5V1B
ARXF42E5V1B

Table of Contents

Other manuals for Daikin RXF20E5V1B

Question and Answer IconNeed help?

Do you have a question about the Daikin RXF20E5V1B and is the answer not in the manual?

Daikin RXF20E5V1B Specifications

General IconGeneral
Cooling Capacity2.0 kW
Heating Capacity2.5 kW
RefrigerantR32
Energy Efficiency Class (Cooling)A++
Energy Efficiency Class (Heating)A+
Power Supply220-240 V, 50 Hz

Summary

General safety precautions

2.2 For the installer

General safety advice specifically for installers.

2.2.1 General installer safety

Provides general safety warnings and advice for installers.

2.2.2 Installation site

Details requirements and restrictions for the installation site.

Installation space requirements

Warns about minimum floor area requirements for R32 refrigerant units.

2.2.3 Refrigerant in case of R410A or R32

Safety precautions related to refrigerants, especially R32.

2.2.4 Electrical

Safety precautions related to electrical installations.

Specific installer safety instructions

Unit installation safety

Safety instructions for unit installation, materials, and legislation.

Installation site safety

Safety precautions for selecting and preparing the installation site.

Refrigerant piping connection safety

Safety guidelines for connecting refrigerant piping with R32 refrigerant.

Refrigerant leakage and fire warnings

Warnings about refrigerant leakage, fire hazards, and using R32 refrigerant.

Wiring, earthing, and cable management

Warnings on wiring, earthing, cable ties, and phase advancing capacitors.

Electrocution risk: servicing and commissioning

Dangers of electrocution during servicing and commissioning.

Maintenance safety precautions

Safety warnings for maintenance: power off, live parts, hot components.

Electrocution risk: compressor servicing

Dangers of electrocution related to compressor servicing.

Explosion risk: compressor handling

Dangers of explosion when removing compressor or using brazing torch.

Burning/scalding risk: compressor

Danger of burning/scalding when touching compressor.

Unit installation

Piping installation

7.2.2 Precautions when connecting the refrigerant piping

Safety precautions for connecting refrigerant piping.

7.3.2 Precautions when checking the refrigerant piping

Precautions for leak checking and vacuum drying.

7.4 Charging refrigerant

Guidelines for charging the refrigerant into the system.

7.4.5 To charge additional refrigerant

Steps for charging additional refrigerant and opening the gas stop valve.

Electrical installation

8.2.2 Precautions when connecting the electrical wiring

Safety precautions for connecting electrical wiring.

Finishing the outdoor unit installation

Commissioning

10.2 Precautions when commissioning

Safety precautions to observe during commissioning.

Maintenance and service

12.2 Maintenance safety precautions

Safety precautions for performing maintenance and service.

Troubleshooting

13.2 Precautions when troubleshooting

Safety precautions to observe during troubleshooting.