Key safety warnings for installation and operation to prevent serious casualties.
Important cautions to prevent injury or equipment damage during installation.
Strict cautions for keeping the R-407C system clean, dry, and tight.
Guidelines for installing the unit and proper handling procedures.
Criteria for selecting a suitable installation location for optimal performance and safety.
Specific precautions for installing units in areas with strong winds or heavy snowfall.
Instructions for ensuring a stable foundation and preventing the unit from falling over.
Proper installation of drain piping to ensure good drainage and prevent water damage.
Required clearances for suction, discharge, and side obstacles in non-stacked setups.
Required clearances for stacked and multi-row unit installations.
Guidelines for refrigerant piping installation, including safety and material compliance.
Table detailing refrigerant pipe sizes for different unit models.
Table defining maximum allowable piping lengths and height differences.
Explanation of the minimum piping length to prevent system overcharging.
Precautions for mixing refrigerants, using tools, and vacuum pumps.
Guidance on installing field pipes in various directions and protecting them.
Method to plug through-holes with insulating material to prevent entry of foreign objects.
Instructions for opening/closing stop valves and related precautions.
Procedure for tightening the service port cover to the specified torque.
Precautions regarding field piping contact with components and insulation requirements.
Dimensions for flare processing and tightening torques for secure connections.
Guidelines for brazing with nitrogen and installing oil traps in piping.
Recommended setup for vacuuming and leak testing refrigerant pipes.
Step-by-step procedure for conducting a leak test on the refrigerant system.
Important safety and procedural precautions for charging refrigerant.
Tables and methods for calculating additional refrigerant based on pipe length.
Illustrative examples for charging refrigerant in different system configurations.
Detailed steps for performing the pumping-down operation to protect the compressor.
Safety guidelines for electrical wiring, including circuit interruption and wire usage.
Methods for properly securing electrical wiring to prevent damage and contact.
Table listing specifications for standard wiring components like fuses and wire types.
Essential checks to perform before starting the test operation.
Step-by-step guide for conducting the test run of the air conditioning unit.
Guidance on interpreting and resolving error codes displayed during test runs.
Methods for diagnosing machine malfunctions using error codes from the remote control.
Guidelines for the safe dismantling and disposal of the unit components.
Explanation of symbols, colors, and abbreviations used in the wiring diagram.
List and definition of electrical components referenced in the wiring diagram.