SiBE041010 Indoor Unit
Removal Procedure 111
1.6 Removal of PCB / Swing Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power
supplies before disassembling work.
Step Procedure Points
1. Remove the shield plate. Preparation
Remove the electrical box
according to the “Removal
of Electrical Box”.
1
Unfasten the hooks at
the upper 2 positions of
the shield plate.
2
Unfasten the hook at
the lower position, and
remove the shield plate
(1).
3
Lift the shield plate (2)
and unfasten the 2
hooks.
4
Slide the shield plate
(2) and remove it.
(R8032)
Hook
shield plate (1)
Hook
(R8033)
(R8034)
Hook
Shield plate (2)

Table of Contents