SiBE041010 Wiring Diagrams
Appendix 145
2. Wiring Diagrams
2.1 Indoor Unit
FTX20/25/35JV1B, ATX20/25/35JV1B
2.2 Outdoor Unit
RX20/25/35JV1B, ARX20/25/35JV1B
LED2 H2P
X1M
3
2
1
LED1 H1P
OUTDOOR
CAUTION
FIELD WIRING.
S1W
INDOOR
10
BLK
9
BLK
9
BLK
S27
R2T
BLK
BLK
RED
H2
V1
GRN
_
BLK
BLK
S26
1
IPM200
_
NOTE)
PCB 1
H1
F1U
3.15A
+
BLK
H3
BLK
4
5
BLK
BLK
1
BLU
12
BLK
S200
3
M1S
OPTION
M1F
1
M
BLK
BLK
1
BLK
+
S32
1
FG
S6
6
1
YLW
2
S601
WHT
RED
2
BLK
9
PCB 3
M
PCB 2
1
BLK
1
ORG
S602
6
RECTIFIER
BLK
S403
BLKBLK
WHT
R1T
S21
BLK
BLK
BLK
1
GRN/YLW
BLK
MR10
BLK
BLK
FG
F1U
H1P~H2P
M1F
M1S
PCB1~PCB3
R1T, R2T
S6~S602
S1W
X1M
: SWING MOTOR
: THERMISTOR
: PROTECTIVE EARTH
: FRAME GROUND
: FUSE
: PILOT LAMP
: FAN MOTOR
: PRINTED CIRCUIT BOARD
: CONNECTOR
: OPERATION SWITCH
: TERMINAL STRIP
H1~H3 : HARNESS
SIGNAL
RECEIVER
TRANSMISSION
CIRCUIT
1. PCB3 SHOWS THE CASE OF
OPTION CONNECTION.
WIRELESS
REMOTE
CONTROLLER
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
3D058454B
L
N
+t˚
3
2
1
S20
MRM10
E2
GRN
S40
1.REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
NOTE
indoor
outdoor
S90
MRM20
SA1
HA1
FIELD WIRING.
ORG
RED
1
Y1E
BRN
YLW
M
BLU
WHT
6
BRN
WHT
ORG
BLK
BLU
RED
YLW
13
IN CASE OF
COOLING ONLY
TYPE
S80
GRN
PTC1
1~
M
DB3
L1R
E1
BLK
BLK
WHT
1
BLK
BLK
S10
BLK
BLK
1
9
S11
BLK
9
BLK
GRN/YLW
N=2
Z2C
C119
C5
C6
HA2
IPM2
FU1
AC2
FU3
BLK
BLK
HR1
MR4, MR30, MRM10
MRM20 : MAGNETIC RELAY
(DISCHARGE)
X1M
M1C : COMPRESSOR MOTOR
R1T, R2T, R3T : THERMISTOR
IPM1, IPM2
: INTELLIGENT POWER MODULE
V1, V2, V3 : VARISTOR
N=3
M1F
R3T
IPM1
SA1 : SURGE ARRESTER
(OUTDOOR)
PTC1 : THERMISTOR PTC
C5, C6, C119 : CAPACITOR
13
L : LIVE
GRY
3
PCB1, PCB2 : PRINTED CIRCUIT BOARD
2
Y1E
: ELECTRONIC EXPANSION VALVE COIL
BLK
V2
DB2
Q1L : OVERLOAD PROTECTOR
V
S70
U
1
R1T
HL2
PCB1
4
PCB2
R2T
S10, S11, S20, S40
S70, S80, S90, HL3
HN3 : CONNECTOR
: PROTECTIVE EARTH
AC1
MR4
HN2
1
Q1L
FU2
V3
BLK
1
3.15A
Z1C
L1R : REACTOR
X1M : TERMINAL STRIP
BLU
MR30
Z1C, Z2C : FERRITE CORE
FU1, FU2, FU3 : FUSE
GRY
M1F : FAN MOTOR
3.15A
12
WHT
IN CASE OF
HEAT PUMP
TYPE
ORG
BLU
YLW
N : NEUTRAL
2
BLK
V1
HN3
6
RED
L
BLK
10
DB1, DB2, DB3 : DIODE BRIDGE
HR2
M1C
U
RED
Y1R : REVERSING SOLENOIDE VALVE COIL
BLK
S
Y1R
20A
1
L1
DB1
7
L1 : COIL
(CONDENSER)
3
WHT
1
3
BRN
V
HL3
1
W
BLK
11
W
N
S80
+
_
~
~
+
_
~
~
+
_
~
~
+
_
+
_
+
_
+
_
+
_
3D058406C