EasyManua.ls Logo

Daikin SiBE041010 - NIGHT SET Mode

Daikin SiBE041010
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SiBE041010 Main Functions
Function and Control 21
1.7 NIGHT SET Mode
Outline When the OFF timer is set, the NIGHT SET Mode is automatically activated. The NIGHT SET
Mode keeps the airflow rate setting.
Detail The NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers it slightly in
the case of heating. This prevents excessive cooling in summer and excessive heating in winter
to ensure comfortable sleeping conditions, and also conserves electricity.
Cooling
Heating
(R12011)
TIMER Operation
NIGHT SET Mode ON
Target temperature
+0.5˚C
temperature shift
Operation stops
at the set hours
1 hour
0.5˚C
2˚C
(R12012)
Target temperature
1 hour later
TIMER operation
NIGHT SET Mode ON

Table of Contents

Related product manuals