EasyManuals Logo

Daikin Super Multi NX FFQ25B8V1B User Manual

Daikin Super Multi NX FFQ25B8V1B
501 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #496 background imageLoading...
Page #496 background image
Wiring Diagrams SiBE121021_C
484 Appendix
4MKS75F2V1B
5MKS90E2V3B
indoor
outdoor
FIELD WIRING
1
3.15A
B
A
YLW
S22
POWER SUPPLY
X4M
4
WHT
M1C
ROOM D
BLU
RED
BLU
WHT
7
3
3
~
YLW
1
W
1
ORG
BLU
7(N)
2
M1F
L1R
8
M
ORG
3
M
1
6
BRN
WHT
S93
5
AC2
L
YLW
1
RED
FU2
D
V5
Z6C
2
2
12
7
1
WHT
SW5
1
WHT
Z3C
GRN
S70
BLU
N
SHEET METAL
6
WHT
1
1
1
RED
YLW
1
S2
MRM10
30A
MRC/W
3
BLK
WHT
BLU
BRN
BLK
SW1
Y1E
SW2
BRN
3
RED
BRN
1
BLU
M
12
GRN
S52
5
BLK
U
BLK
GRN
GRY
1
S20
SW4
8
BLU
YLW
1
BLU
C
L
BLK
3.15A
FU3
3
Z2C
BRN
X1M
S23
1
S101
WHT
RED
1
M
PM1
YLW
AC1
PCB1
BLU
Z5C
6
BLU
YLW
LED
M
RED
V
2
9
U
6
GRY
HR1
3
2
Z4C
Y3E
E1
BLK
1
X3M
Y4E
BLU
B
BLU
X11A
YLW
YLW
RED
ORG
ROOM A
BLU
YLW
BLK
WHT
RED
1
5
BLU
MRM20
BLU
Y2E
V2
D
BLU
ORG
V9
BLU
W
C
2
BLK
2
3
Z1C
BLU
S21
BLU
9
PCB2
ROOM C
E2
2
S15
RED
6
ORG
4
2
FU1
V100
1
1
BLK
5
3
3
A
V3
1
3
X5M
43
BLU
M
1
WHT
S102
6(P)
Q1L
ORG
WHT
2
WHT
BLK
N
BLU
1
1
BRN
V
3
A
X2M
WHT
BRN
1
S51
BLK
S90
SW3
S10
S80
GRN
RED
1
S92
RED
BLU
BLU
SA2
S40
HR2
BLK
t° t° t° t° t° t° t° t° t°t° t°
+++
(ROOM-B)
R9T
<GAS PIPE>
R8T R5TR2T R6TR3T
<LIQUID PIPE>
R10T
R4TR1T
R11T
(ROOM-A) (ROOM-C)
R7T
(ROOM-D) (ROOM-B)
(ROOM-A) (ROOM-C)
(ROOM-D)
TO INDOOR UNIT
ROOM B
(OUTDOOR) (DISCHARGE)
(CONDENSER)
Z1C~Z6C
X1M~X5M
Y1E~Y4E
V2, V3, V5, V9, V100
SA2
FU1, FU2, FU3
AC1, AC2
U, V, W, X11A
E1, E2
HR1, HR2
: FERRITE CORE
: TERMINAL STRIP
: ELECTRONIC EXPANSION VALVE COIL
: VARISTOR
: SURGE ARRESTER
: FUSE
: CONNECTOR
MRM10, MRM20
MRC/W
R1T~R11T
S2~S102
LED1~LED4
LEDA
: MAGNETIC RELAY
: THERMISTOR
: CONNECTOR
: PILOT LAMP
L
N
SW1
SW2
SW3
SW4
SW5
: LIVE
: NEUTRAL
: FORCED OPERATION ON/OFF SW (SW1)
: SELECT SW (SW2)
: WIRING ERROR CHECK SW (SW3)
: PRIORITY ROOM SETTING SW (SW4)
: NIGHT QUIET MODE SETTING SW (SW5)
M1C
M1F
L1R
Q1L
PM1
PCB1, 2
SHEET METAL
: COMPRESSOR MOTOR
: FAN MOTOR
: REACTOR
: OVERLOAD PROTECTOR
: POWER MODULE
: PRINTED CIRCUIT BOARD
: TERMINAL STRIP FIXED PLATE
3D055885
2TW57596-1
L: Live, N: Neutral, : Field wiring
: Terminal strip : Connector : Connection
Room C
Room A
Room A
Room B
Room C
Room D
Room E
Room A
Room B
Room C
Room D
Room E
Condenser
Discharge
Outdoor
Gas pipe
Liquid pipe
Room D
Room E
Indoor
Outdoor
Sheet
metal
BLK: Black
BRN: brown
WHT: White
RED: Red
BLU: Blue
GRY: Grey
ORG: Orange
YLW: Yellow
GRN: Green
To indoor unit
Room B
: Protective earth (screw) : Relay connector
: Terminal
Z1C~Z6C
X1M~X6M
Y1E~Y5E
V2,V3,V5
V9,V100
SA2
FU1,FU2,FU3
AC1,AC2
U,V,W,X11A
E1,E2E
HR1,HR2
MRM10,MRM20
MRC/W
: Ferrite core
: Terminal strip
: Electronic expansion valve coil
: Varistor
: Surge arrester
: Fuse
: Connector
: Magnetic relay
R1T~R3T
R4T~R8T
R9T~R13T
S2~S102
LED1~LED5
LEDA
SW1
SW2
SW3
SW4
SW5
M1C
M1F
L1R
: Thermistor
: Connector
: Light emitting diode
: Forced operation on/off switch (SW1)
: Operation mode select SW (SW2)
: Wiring error check SW (SW3)
: Priority room setting SW (SW4)
: Night quiet mode setting SW (SW5)
: Compressor motor
: Fan motor
: Reactor
Q1L
PM
PCB1,2
Sheet metal
F2U
Q1DI
: Overload protector
: Power module
: Printed circuit board
: Terminal strip fixed plate
: Field fuse
: Field earth leakage breaker
(300mA)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Super Multi NX FFQ25B8V1B and is the answer not in the manual?

Daikin Super Multi NX FFQ25B8V1B Specifications

General IconGeneral
BrandDaikin
ModelSuper Multi NX FFQ25B8V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals