Specifications EDUS121131
38 SUPER MULTI NX 2/3/4MXS-G/J Series Heat Pump
09+09+12+12
Wall Duct Duct Duct 6.63 6.63 9.27 9.27 31.80 12.00 ~ 33.30 2980 1020 ~ 3300 14.6 5.0 ~ 16.2 98
09+09+12+12
Duct Duct Wall Wall 6.73 6.73 9.42 9.42 32.30 12.00 ~ 33.80 2980 960 ~ 3240 14.6 4.7 ~ 15.9 98
09+09+12+12
Duct Duct Wall Duct 6.63 6.63 9.27 9.27 31.80 12.00 ~ 33.30 2980 1020 ~ 3300 14.6 5.0 ~ 16.2 98
09+09+12+12
Duct Duct Duct Duct 6.54 6.54 9.16 9.16 31.40 12.10 ~ 32.90 3050 1090 ~ 3380 15.0 5.3 ~ 16.6 98
09+09+12+15
Wall Wall Wall Wall 6.22 6.22 8.72 12.44 33.60 11.70 ~ 34.60 3020 840 ~ 3180 14.8 4.1 ~ 15.6 98
09+09+12+15
Wall Wall Wall Duct 6.15 6.15 8.60 12.30 33.20 11.80 ~ 34.20 3040 970 ~ 3250 14.9 4.8 ~ 15.9 98
09+09+12+15
Wall Wall Duct Wall 6.15 6.15 8.60 12.30 33.20 11.80 ~ 34.20 2950 890 ~ 3160 14.5 4.4 ~ 15.5 98
09+09+12+15
Wall Wall Duct Duct 6.07 6.07 8.51 12.15 32.80 11.90 ~ 33.80 3050 1020 ~ 3260 15.0 5.0 ~ 16.0 98
09+09+12+15
Wall Duct Wall Wall 6.15 6.15 8.60 12.30 33.20 11.80 ~ 34.20 2950 890 ~ 3160 14.5 4.4 ~ 15.5 98
09+09+12+15
Wall Duct Wall Duct 6.07 6.07 8.51 12.15 32.80 11.90 ~ 33.80 3050 1020 ~ 3260 15.0 5.0 ~ 16.0 98
09+09+12+15
Wall Duct Duct Wall 6.07 6.07 8.51 12.15 32.80 11.90 ~ 33.80 2960 930 ~ 3110 14.5 4.6 ~ 15.3 98
09+09+12+15
Wall Duct Duct Duct 5.98 5.98 8.38 11.96 32.30 11.90 ~ 33.30 3030 1080 ~ 3230 14.9 5.3 ~ 15.8 98
09+09+12+15
Duct Duct Wall Wall 6.07 6.07 8.51 12.15 32.80 11.90 ~ 33.80 2960 930 ~ 3110 14.5 4.6 ~ 15.3 98
09+09+12+15
Duct Duct Wall Duct 5.98 5.98 8.38 11.96 32.30 11.90 ~ 33.30 3030 1080 ~ 3230 14.9 5.3 ~ 15.8 98
09+09+12+15
Duct Duct Duct Wall 5.98 5.98 8.38 11.96 32.30 11.90 ~ 33.30 2930 990 ~ 3130 14.4 4.9 ~ 15.4 98
09+09+12+15
Duct Duct Duct Duct 5.91 5.91 8.27 11.81 31.90 12.00 ~ 32.90 3070 1140 ~ 3280 15.1 5.6 ~ 16.1 98
09+12+12+12
Wall Wall Wall Wall 6.45 9.05 9.05 9.05 33.60 11.90 ~ 34.50 3020 840 ~ 3180 14.8 4.1 ~ 15.6 98
09+12+12+12
Wall Wall Wall Duct 6.38 8.94 8.94 8.94 33.20 11.90 ~ 34.20 3040 900 ~ 3200 14.9 4.4 ~ 15.7 98
09+12+12+12
Wall Wall Duct Duct 6.31 8.83 8.83 8.83 32.80 12.00 ~ 33.80 3030 960 ~ 3240 14.9 4.7 ~ 15.9 98
09+12+12+12
Wall Duct Duct Duct 6.20 8.70 8.70 8.70 32.30 12.00 ~ 33.30 3090 1020 ~ 3300 15.2 5.0 ~ 16.2 98
09+12+12+12
Duct Wall Wall Wall 6.38 8.94 8.94 8.94 33.20 11.90 ~ 34.20 3040 900 ~ 3200 14.9 4.4 ~ 15.7 98
09+12+12+12
Duct Wall Wall Duct 6.31 8.83 8.83 8.83 32.80 12.00 ~ 33.80 3030 960 ~ 3240 14.9 4.7 ~ 15.9 98
09+12+12+12
Duct Wall Duct Duct 6.20 8.70 8.70 8.70 32.30 12.00 ~ 33.30 3090 1020 ~ 3300 15.2 5.0 ~ 16.2 98
09+12+12+12
Duct Duct Duct Duct 6.13 8.59 8.59 8.59 31.90 12.10 ~ 32.90 3160 1090 ~ 3380 15.5 5.3 ~ 16.6 98
Combination
of
indoor unit
Type of indoor unit
Capacity of each indoor unit
Each capacity (kBtu/h) Total capacity (kBtu/h) Total input (W) Total current (A)
Power
factor (%)
A room B room
C room D room
A room B room
C room D room
Rating ( min ~ max ) Rating ( min ~ max ) Rating ( min ~ max ) Rating
Note:
1. Cooling capacity is based on 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB) (Indoor temperature), 95°FDB
(35°CDB) / 75°FWB (24°CWB) (Outdoor temperature).
Heating capacity is based on 70°FDB (21°CDB) / 60°FWB (15.6°CWB) (Indoor temperature), 47°FDB
(8.3°CDB) / 43°FWB (6°CWB) (Outdoor temperature).
2. The total ability of connected indoor units is up to 45.0 kBtu/h.
3. It is impossible to connect only one indoor unit.
4. Wall type of indoor unit: CTXS-L, FTXS-L series
Duct type of indoor unit: CDXS-L, FDXS-L series
3D078864
3D078865
3D078866
3D078867
3D078868
3D078869
3D078870
3D078871