120 Operational Reference Nano Series GigE Vision Camera
Synchronous ModeExposure Timing Specifications
For single and multi-frame synchronous exposures, the following timing values of different Sony
models are specified in the following table. Refer to the previous graphics.
Variable Sony Models Timing Value
a
all 0 to 1 horizontal line time (in µsec)
b
All except M/C810 2x horizontal line time (in µsec) + plus any user set ExposureDelay
b
M/C810 4x horizontal line time (in µsec) + plus any user set ExposureDelay
c
M/C810 8x horizontal line time (in µsec) 4.997 µsec
c
M/C700 & M/C1450 15x horizontal line time (in µsec) - 14.26 µsec
c
M/C1920 & M/C1940 10x horizontal line time (in µsec) - 13.73 µsec
c
M/C1950 8x horizontal line time (in µsec) 13.73 µsec
c
M/C2020 & M/C2420 8x horizontal line time (in µsec) 13.73 µsec
c
M/C2050 & M/C2450 10x horizontal line time (in µsec) - 13.73 µsec
c
M/C4020 & M/C4030 8x horizontal line time (in µsec) - 14.26 µsec
c
M/C4040 & M/C4060 21x horizontal line time (in µsec) - 14.26 µsec
d
M/C810 Minimum: 13x horizontal line time (in µsec) 4.997 µsec
d
M/C700 & M/C1450 Minimum: 18x horizontal line time (in µsec) - 14.26 µsec
d
M/C1920 & M/C1940 Minimum: 13x horizontal line time (in µsec) 13.73 µsec
d
M/C1950 Minimum: 11x horizontal line time (in µsec) 13.73 µsec
d
M/C2020 & M/C2420 Minimum: 11x horizontal line time (in µsec) 13.73 µsec
d
M/C2050 & M/C2450 Minimum: 13x horizontal line time (in µsec) 13.73 µsec
d
M/C4020 & M/C4030 Minimum: 11x horizontal line time (in µsec) - 14.26 µsec
d
M/C4040 & M/C4060 Minimum: 24x horizontal line time (in µsec) - 14.26 µsec