EasyManua.ls Logo

d&b audiotechnik 10D - AutoStandby and Wakeup Functionality; AutoStandby;Wakeup Settings Configuration

d&b audiotechnik 10D
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12.5.7. AutoStandby
Selecting «AutoStandby» opens the corresponding subscreen with
the «Settings» tab being active.
The AutoStandby function automatically switches the amplifiers to
Standby mode after a predefined time when the incoming signal
level at the individually specified inputs drops below a defined
threshold. The function is independent of the mute status of the
respective channels.
The AutoWakeup function automatically repowers the amplifier
within 5 seconds when an input signal is present and exceeds a
defined threshold.
Note: The AutoWakeup function only applies to the digital
inputs.
Settings tab
Mode
Off:
Disables the function.
AutoStandby:
Enables the function. When the function is
activated, the device will switch to Standby
mode after the predefined time.
AutoStandby&AutoWakeup:
Enables the function. When the function is
activated, the device will switch to standby
mode after the predefined time and will be
repowered within 5 seconds when an input
signal is present and exceeds the defined
threshold.
Time to
standby
Time (count down), adjustable from 1 min. to
24 h. in 1 min. increments.
Threshold Threshold for the AutoWakeup function,
adjustable from –140 dBu to +25 dBu in
1 dBu increments.
Remaining
time to
standby
Non-editable information field. In addition to
the count down of the remaining time, various
status details are displayed depending on the
given settings.
Inputs tab
When the AutoWakeup function is enabled, the corresponding
inputs that will be monitored for incoming signals can be specified.
d&b 10D/30D Manual 1.10 en 59