EasyManua.ls Logo

d&b audiotechnik 30D - Device and Channel Strip Display; Header Area: Device Information; Data Area: Channel Strip Details

d&b audiotechnik 30D
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.1. Header area - Device
(from left to right):
Power on indicator
Yellow Indicates the start up phase of the power supply.
Green Indicates that the unit is switched on.
Red Indicates a device error.
Device view button
The device name and the output mode are displayed. This button
provides direct access to the Device setup screen.
ID
The Remote «ID» is displayed. This navigation button also provides
direct access to the Remote subscreen.
Power button
The «Power» button provides the following functions:
Cancel the sequence.
Mute all Master mute.
To unmute the channels, use the individual Channel
mute buttons.
Standby In Standby mode the device idles drawing minimal
power consumption. Only the most essential
functions are provided. The screen and network
remain functional.
9.2. Data area - Channel strip(s)
The data area features the actual channel strips starting with the
input connector and then following the real signal flow from left to
right. All vital information is displayed. This includes:
Input signal present (ISP)
Input routing
Channel configuration,
Controller output signal (OSP)
Channel mute buttons and status.
Error messages