14.4. Current/power draw and thermal dissipation
Measurement references
Signal CF 12 dB: Represents 1/8th of the nominal power.
Signal CF 9 dB: Represents 1/4th of the nominal power; power
is limited to the nominal line current.
Continuous (cont.): Unlimited time. Thermal conditions may
affect power figures.
Maximum (max.): Values are measured 1 sec. after signal was
applied.
Sine wave (Max. 1 s / 10 %): 1 kHz Sine wave with
(voltage) CF 3 dB / 1.4, resp. Represents the highest line current
draw.
10D Amplifier
230 V AC / 50 Hz / 0.5 Ω Source impedance
Mode/Signal Load
Line
current
A
RMS
Power
factor
Input
power
W
Output
power
(sum.) W
Power
loss
W
Thermal
dissipation
BTU/hr
Thermal
dissipation
kCal/hr
OFF – 0.2 0.1 4 0 4 14 3
Standby – 0.23 0.23 13 0 13 44 11
Idling – 0.37 0.5 45 0 45 154 39
Signal CF 12 dB cont. 4 Ω/Ch. 2.5 0.89 516 390 126 430 108
Signal CF 9 dB cont. 4 Ω/Ch. 4.86 0.96 1070 780 290 989 249
Signal CF 9 dB max. 4 Ω/Ch. 5.9 0.94 1296 800 496 – –
Sine wave CF 3 dB
Max. 1 s / 10 %
4 Ω/Ch. 16.2 – – – – – –
208 V AC / 60 Hz / 0.5 Ω Source impedance
Mode/Signal Load
Line
current
A
RMS
Power
factor
Input
power
W
Output
power
(sum.) W
Power
loss
W
Thermal
dissipation
BTU/hr
Thermal
dissipation
kCal/hr
OFF – 0.21 0.1 4 0 4 14 3
Standby – 0.25 0.22 13 0 13 44 11
Idling – 0.41 0.53 45 0 45 154 39
Signal CF 12 dB cont. 4 Ω/Ch. 2.7 0.91 516 390 126 430 108
Signal CF 9 dB cont. 4 Ω/Ch. 5.3 0.97 1085 780 305 1041 262
Signal CF 9 dB max. 4 Ω/Ch. 5.5 0.97 1140 800 340 – –
Sine wave CF 3 dB
Max. 1 s / 10 %
4 Ω/Ch. 17 – – – – – –
d&b 10D/30D Manual 1.10 en 79