120 V AC / 60 Hz / 0.2 Ω Source impedance
Mode/Signal Load
Line
current
A
RMS
Power
factor
Input
power
W
Output
power
(sum.) W
Power
loss
W
Thermal
dissipation
BTU/hr
Thermal
dissipation
kCal/hr
OFF – 0.2 0.05 1 0 1 5 1
Standby – 0.2 0.3 7 0 7 25 6
Idling – 0.47 0.67 39 0 39 131 33
Signal CF 12 dB cont. 4 Ω/Ch. 5.6 0.94 630 390 240 819 206
Signal CF 9 dB cont. 4 Ω/Ch. 8.5 0.99 1010 740 270 921 232
Signal CF 9 dB max. 4 Ω/Ch. 9.5 0.99 1120 800 320 – –
Sine wave CF 3 dB
Max. 1 s / 10 %
4 Ω/Ch. 20.7 – – – – – –
100 V AC / 60 Hz / 0.2 Ω Source impedance
Mode/Signal Load
Line
current
A
RMS
Power
factor
Input
power
W
Output
power
(sum.) W
Power
loss
W
Thermal
dissipation
BTU/hr
Thermal
dissipation
kCal/hr
OFF – 0.2 0.05 1 0 1 3 1
Standby – 0.2 0.32 7 0 7 22 6
Idling – 0.53 0.71 38 0 38 130 33
Signal CF 12 dB cont. 4 Ω/Ch. 6 0.99 600 380 220 751 189
Signal CF 9 dB cont. 4 Ω/Ch. 9.1 0.99 910 625 285 972 245
Signal CF 9 dB max. 4 Ω/Ch. 11.8 0.99 1180 800 380 – –
Sine wave CF 3 dB
Max. 1 s / 10 %
4 Ω/Ch. 22.6 – – – – – –
d&b 10D/30D Manual 1.10 en80