Id Display text Eventlog text Description Location Possible reasons
46 Amp. firmware is too
old
Amp. firmware
version %4.2d is too
old, required is
%4.2d
Amp firmware version
is older than required
Amp Amp software error.
50 Invalid device para Channel '%c': invalid
device parameters
(device ident %d)
Invalid device
parameters
DSP Software error or
wrong device type
detected.
51 Invalid DSP prog %u Channel '%c' : invalid
DSP program %d
DSP program invalid DSP Software error.
52 DSP boot error Channel '%c': DSP
boot error (DSP
program %d)
DSP boot error DSP DSP or software
error.
58 DSP comm. error Channel '%c': DSP
communication error
DSP communication
fault
DSP DSP defect or
software error.
59 Invalid setup data Channel '%c': invalid
speaker setup
(speaker id %d, no.
%d, err %d)
DSP invalid setup
data
DSP Software error.
61 Invalid AP slot %d Channel '%c': invalid
AP slot %d (file
version %d)
Invalid
ArrayProcessing data
(External: AP data file
invalid)
Software error.
78 Amp. supply fault Amp. supply fault
(status %04X, err
%04X, %4.1dV,
%4.1dV)
Amp rail voltages
Amp Amp defect.
79 Amp. firmware
mismatch
Amp. firmware V%d.
%02d.%02d not
suitable for hardware
ident %d
Amp has wrong
firmware
Amp Amp firmware does
not support the Amp
hardware.
87 Amp temp. mute Channel '%c': Amp.
temperature auto
shutdown (%d°C)
Amp mute due to
high temperature
Amp Poor cooling.
89 Amp. protection Channel '%c': Amp.
protection (power
%uW)
Amp channel
protection
Amp cabling or Amp
defect.
95 Amp. overtemp %dÂ
°C
Channel '%c': Amp.
overtemperature %dÂ
°C (power %uW)
Amp over
temperature
Amp Poor cooling.
96 Amp. temp sensor
fault
Amp. temperature
sensor fault (A %dÂ
°C, B %d°C, C
%d°C, D %d°C)
Amp temperature
sensor fault
Amp Amp defect.
99 Amp. temp warn
%d°C
Channel '%c': Amp.
temperature warning
%d°C (power
%uW)
Amp temperature
warning
Amp Poor cooling.
120 CAN open error Could not open CAN
interface (error %d)
CAN interface open
error
DSP DSP defect or
software error.
121 CAN error CAN error %d
(remote flags %02X,
dbCan flags %02X)
CAN error (External: CAN
cabling), RemId
CAN cabling or
multiple RemIds.
d&b 10D/30D Manual 1.10 en90