Notes:
In "2-Way Active mode" the "Link A»B" is used permanently to link the
channels and cannot be modified. In this mode also the "MUTE A" and
the "MUTE B" switches are linked. Therefore the device can be
muted/unmuted by either the "MUTE A" or "MUTE B" switch. After
leaving "2-Way Active mode" the "Link A»B" will be set to "off".
AmpPreset
D12 amplifiers from firmware version V2.12 provide AmpPresets which
contain all important user settings of the whole device like input, output
and channel configurations, EQ and delay settings.
Using the D12 AmpPresets a sound system can be operated in different
configurations (e.g. "Conference", "Music" or "Emergency Call") without
the need of transmitting all the detailed settings of the devices used.
There are three types of AmpPreset memories:
User: Nine AmpPresets which can be accessed locally or via the d&b
Remote network (R10 Service software from V1.0.6). These AmpPresets
are used to set the complete D12 to a previously defined configuration
for a particular application and can be named individually.
Alarm: Three AmpPresets which can only be accessed via the d&b
Remote network (R10 Service software from V1.0.6). Intended for use in
alarm systems to protect the system settings against local modifications.
Backup: Three AmpPresets which can only be accessed the d&b
Remote network (R10 Service software from V1.0.6). Intended for
temporary use to backup the current system settings when another
AmpPreset is loaded.
Selecting "AmpPreset" and pushing the encoder enters the sub-menu.
The D12 menu item AmpPreset indicates the last loaded AmpPreset
number and will be marked with "
" if any settings had been modified
since loading. The menu below provides the functions Select, Load,
Save, Clear and a name field to manage the AmpPresets.
Select
Turning and pushing the encoder provides access to the nine user preset
memories to be loaded, saved or cleared.
To load, save or clear the selected AmpPreset first scroll to the
respective menu item (Load, Save or Clear) and push the encoder to
select the desired function. "O.k.?" will appear (flashing) to confirm the
selected function.
Load
Restore the settings of a stored AmpPreset.
Save
Store the current amplifier settings into the selected preset memory and
name it.
Clear
The selected AmpPreset memory will be cleared and "empty" will be
displayed.
D12 Software manual (Firmware V2.x.x) (5.2EN) Page 19 of 36
AmpPreset
1
*
Back
Select
9
Preset Name
Load
Save
Clear
AmpPreset 1
AmpPreset
1
*
Back
Select
9
MyPreset
Load Save Clear Ok?
Load Save Clear Ok!
AmpPreset
1
Back
Select
9
(empty)
- - - - Save Clear
*