Temp. PS
The temperature of the D12 Power Supply.
Hardware
Hardware type and variant [t.vvv] and identification [cn].
Firmware
The version of software installed in the D12.
DSP-Ver
The version of active software installed in the D12 DSPs.
S/N
Serial number of the device.
Log
Selecting "Log" and pushing the encoder enters the sub-menu.
The log book contains information relating to the use and environmental
conditions experienced throughout the operating life of the D12.
The bar graphs indicate the time the D12 had been in certain condition
related to the total time the device has been connected to mains power
supply and switched on.
For example a half filled "Standby bar graph" would indicate that the
D12 has been in "Standby mode" for half its operating life.
The following information will be recorded:
On time
Hours counter. Indicating the amount of time the D12 has been
connected to a mains power supply and switched on.
Starts
How often the device had been switched on.
Standby
Proportion of the "On Time" the D12 has been in Standby mode.
SysErr
A numerical value indicating the number of times the D12 has entered
the error condition "SysErr".
RemoteErr
A numerical value indicating the number of times the D12 has entered
the error condition "RemoteErr".
DSP Halt
A numerical value indicating the number of times the D12 has entered
the error condition "DSP Halt" due to a internal fault.
PS Log
Selecting "PS Log" and pushing the encoder enters the sub-menu.
PS Err
A numerical value indicating the number of times the D12 has entered
the error condition "PS Err".
Overvolt.
A numerical value indicating the number of times the D12 has entered
the error condition "Overvoltage".
Temp Off
A numerical value indicating the number of times the D12 has switched
off with the error condition "Overtemperature" due to overheating.
D12 Software manual (Firmware V2.x.x) (5.2EN) Page 24 of 36
Temp.PS. 36°C
Hardware t.vvv cn
Firmware D12 Xn.n.nn
DSP-Ver Xn.nn Xn.nn
S/N Z2600nnnnnnnn
Log
Overvolt. 0x
Temp Off 0x
<40°C
. . .