Device setup
6.5.1.3 Preferences/More
Select the «More» tab to open the corresponding subscreen which
provides the following options.
Buzzer
The internal buzzer serves as an acoustic signal in case of a device
or channel error.
The following settings can be enabled:
Off The internal buzzer is switched off.
On The internal buzzer is switched on and generates an
intermittent sequence of two equal tones.
Single The internal buzzer generates an intermittent single
tone.
Melody The internal buzzer generates a predefined
intermittent sequence of tones.
Set clock
Enables setting the internal clock while the current UTC
(Coordinated Universal Time) date and time are displayed at the
bottom of the screen.
Within a Remote network, the device's clock is synchronized to the
UTC time of the connected R1 instance.
6.5.1.3.1 System reset
Selecting «Clear all device settings to default» resets all device
settings to factory defaults except for the network (Ethernet) and
fixed device settings.
To prevent accidental reset when you tap the «Clear...» button, a
dialog will pop up prompting you to confirm the reset or cancel the
sequence by tapping the Back button (
).
Alternative procedure
A system reset can also be triggered as follows:
Note: All device preferences will be set to factory defaults
except for the network (Ethernet) and fixed device settings.
If you execute this procedure, no dialog will be prompted and
the reset will start immediately.
1. Switch off the device.
2. Press and hold the encoder and repower the device.
↳
Long confirmation beep.
3. Release the encoder and briefly press the encoder again
within 2 sec.
↳
Short confirmation beep.
The device will boot up and will switch to the Home screen.
A corresponding message will be issued:
d&b D40 Reference manual 1.5 en 35