Device setup
6.5.5 Energy saving
EcoMode
EcoMode enables the amplifier to automatically switch between
normal and low power consumption modes depending on the
current output level requirements. When enabled and the output
level of all channels is continuously low, a 60 second countdown
will be started, indicated by the message
«Counting down to EcoMode» in the bottom left corner.
When the output signals has been low for the full 60 seconds,
EcoMode will be activated and power consumption is reduced.
This is indicated by the green LED on the «Eco» button, the text
«EcoMode» in the bottom left corner and the text «Eco» on the
power button.
In EcoMode, the amplifier still outputs the audio input signals.
Once the output level of any channel exceeds the amplifier's
capabilities in EcoMode, the amplifier automatically switches back
to normal operation without interruption of the audio output
signals.
Note: Switching from low to normal mode may be
accompanied by audible compression during the first 300 ms.
AutoStandby & AutoWakeup
Mode
Off:
Disables the functions.
AutoStandby:
Enables the function.
When the function is activated and the input
signal has not exceeded the defined
«Threshold», the device switches to Standby
mode after the predefined «Time to Standby».
You can repower the amplifier at any time by
selecting the «Power» button.
AutoStandy + AutoWakeup:
Enables the function.
Switching to Standby mode takes place in two
stages:
1. ReadyStandby
When the signal drops below the defined
«Threshold», the device switches to
ReadyStandby mode after the predefined
«Time to Standby».
2. Standby
The device switches to Standby mode after
another two «Time to Standby» periods.
The amplifier will be repowered within less
than 4 seconds as soon as an input signal is
present and exceeds the defined «Threshold».
Time to
Standby
Time (countdown), adjustable from 1 min. to
24 h in 1 min. increments.
Threshold Threshold for the AutoStandby and
AutoWakeup functions, adjustable from
–140 dBFS to 0 dBFS in 1 dB increments.