Channel setup
Clear... To prevent accidental reset when you tap the
«Clear...» button, a dialog will pop up prompting
you to confirm the reset or cancel the sequence
by tapping the Back button ( ).
Selecting the «Clear...» button clears/resets the
following loudspeaker related settings of the
respective channel.
Configuration switches (Filter_1, Filter_2,
Filter_3) are reset.
Level is set to 0 dB.
Delay settings are reset (the selected unit will
be kept).
All EQ settings are disabled.
Load and Input monitoring are set to off.
The respective channel is muted and the
selected setup is activated.
Array
Processing
For applicable loudspeakers, the
«ArrayProcessing» button becomes functional. It
indicates the On/Off status of the function and
provides direct access to the ArrayProcessing
subscreen, which is described in
Þ Chapter 7.8.1 "ArrayProcessing" on page 52.
Note: ArrayProcessing does not apply to all
loudspeakers. When the function is not
applicable, this button is not functional.
LoadMatch For applicable loudspeakers, the «LoadMatch»
button becomes functional. It Indicates the
On/Off status of the function and provides direct
access to the LoadMatch subscreen which is
described in Þ Chapter 7.8.2 "LoadMatch"
on page 53.
Note: LoadMatch does not apply to all
loudspeakers. When the function is not
applicable, this button is not functional.