EasyManua.ls Logo

d&b audiotechnik J Series - 6. Care and Maintenance; Disposal; 6.1. Transport and Storing; 6.2. Visual and Functional Inspection; 6.3. Disposal

d&b audiotechnik J Series
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6. Care and maintenance / Disposal
6.1. Transport / Storing
During transport ensure the rigging components are not stressed or
damaged by mechanical forces. Use suitable transport cases.
Due to their surface treatment the J-Series rigging components are
temporarily protected against moisture. However, ensure the
components are in a dry state while stored or during transport and use.
6.2. Visual and functional inspection
Cabinet enclosure:
Visual inspection of all fitting plates for obvious damage (e.g. cracks
or corrosion).
Inspection of all fitting plates including front grills to ensure they are
securely attached.
Regularly lubricate the sockets with WD-40
®
or a similar product.
Locking pins
Visual inspection regarding deformation and corrosion of the
component.
Inspection for missing ball bearings and damage.
Functional inspection of the release mechanism to check it functions
properly.
Regularly lubricate Locking pins with WD-40
®
or a similar product.
Front and Splay (Rear) links
Visual inspection regarding deformation and damage (e.g. cracks and
corrosion) including all drilled holes of the component.
Z5300 J Flying frame
Visual inspection regarding deformation and damage (e.g. cracks
and corrosion) including all drilled holes of the component.
Regularly check the flatness of the Flying frame. For this purpose
position the Flying frame on a flat surface and visually check the
frame for deformation and/or torsion. For obvious deformation
and/or torsion contact d&b audiotechnik for further advice and how
to proceed.
Z5303 J Safety chain
Z5305 J Hoist connector chain
Inspection according to the appropriate regulations for lifting devices
(EN 818-6:2000 Regularly inspection within a 12 month period.
Regularly inspection for cracks within a 36 month period).
6.3. Disposal
When out of use the rigging components must be disposed in
accordance to the national environmental regulations.
Ensure that damaged rigging components are disposed in a way that
they can not be used again.