5.0 Troubleshooting
Symptom Cause How to solve
Noise from
the unit
If a-type unit: on rare occa-
sions, vibration can occur if unit
is mounted directly onto the
joists. Unit should be mounted
on a suitable platform.
If w-type unit: If the rubber spac-
ers have not been fitted at the
rear of the unit or if the silicone
strip was not fitted onto the wall
bracket.
A defective fan bearing will
produce a grinding noise’.
For a-type models:
Check that unit has platform acc. to
installation manual.
For w-type models:
Check that rubber spacers and
silicone strip were fitted.
If fan ball bearing is suspected to be
defective, contact your installer.
Noise from
Air valves
Air flow is too high.•
Pressure is too high over valve.•
No silencer has been fitted to •
main duct.
In a correctly sized system, noise
will not be a problem. However, if
the air valves are accidently closed
during cleaning, this can cause a
hissing noise - so avoid turning the
valves when cleaning the ceiling.
Frost icon
on the display
Low outdoor temperatures
entail a risk of ice forming in the
heat exchanger - the system is in
defrost mode.
This is not an error, but a standard
mode. The function stops automati-
cally when the outdoor tempera-
ture rises.