[2157] Ext. 3 Reference [Unit] The value of the reference for extended Closed Loop Controller 3
[2158] Ext. 3 Feedback [Unit] The value of the feedback signal for extended Closed Loop Controller 3
[2159] Ext. Output [%] The value of the output from extended Closed Loop Controller 3
[2230] No-Flow Power The calculated No Flow Power for the actual operating speed
[2580] Cascade Status Status for the operation of the Cascade Controller
[2581] Pump Status Status for the operation of each individual pump controlled by the Cascade Controller
[2791] Cascade Reference Reference output for use with follower drives.
[2792] % Of Total Capacity Readout parameter to show the system operating point as a % capacity of total system capacity.
[2793] Cascade Option Status Readout parameter to show the status of the cascade system.
0-21 Display Line 1.2 Small
Option: Function:
Select a variable for display in line 1, middle position.
[1662] * Analog input 53 The options are the same as those listed for par. 0-20
Display Line 1.1 Small
.
0-22 Display Line 1.3 Small
Option: Function:
Select a variable for display in line 1, right position.
[1614] * Motor Current The options are the same as those listed for par. 0-20
Display Line 1.1 Small
.
0-23 Display Line 2 Large
Option: Function:
Select a variable for display in line 2.
[1615] * Frequency The options are the same as those listed for par. 0-20
Display Line 1.1 Small
0-24 Display Line 3 Large
Option: Function:
[1652] * Feedback [Unit] The options are the same as those listed for par. 0-20
Display Line 1.1 Small
.
Select a variable for display in line 2.
0-37 Display Text 1
Range: Function:
0 N/A* [0 - 0 N/A] In this parameter it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If to be displayed permanently select Display Text 1 in par. 0-20
Display
Line 1.1 Small
, par. 0-21
Display Line 1.2 Small
, par. 0-22
Display Line 1.3 Small
, par. 0-23
Display
Line 2 Large
or par. 0-24
Display Line 3 Large
. Use the
or
buttons on the LCP to change a
character. Use the
and
buttons to move the cursor. When a character is highlighted by the
cursor, it can be changed. Use the
or
buttons on the LCP to change a character. A character
can be inserted by placing the cursor between two characters and pressing
or
.
0-38 Display Text 2
Range: Function:
0 N/A* [0 - 0 N/A] In this parameter it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If to be displayed permanently select Display Text 2 in par. 0-20
Display
Line 1.1 Small
, par. 0-21
Display Line 1.2 Small
, par. 0-22
Display Line 1.3 Small
, par. 0-23
Display
Line 2 Large
or par. 0-24
Display Line 3 Large
. Use the
or
buttons on the LCP to change a
character. Use the
and
buttons to move the cursor. When a character is highlighted by the
cursor, this character can be changed. A character can be inserted by placing the cursor between
two characters and pressing
or
.
6 How to Programme the Low Harmonic Drive
VLT AQUA Low Harmonic Drive Operating In-
structions
92 MG.20.T1.02 - VLT
®
is a registered Danfoss trademark
6

Table of Contents

Other manuals for Danfoss vlt aqua

Related product manuals