4.1.6 3-** Reference/Ramps
Par.
No. #
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
3-0* Reference Limits
3-00 Reference Range null All set-ups TRUE - Uint8
3-01 Reference/Feedback Unit null All set-ups TRUE - Uint8
3-02 Minimum Reference App.Dependent All set-ups TRUE -3 Int32
3-03 Maximum Reference App.Dependent All set-ups TRUE -3 Int32
3-04 Reference Function [0] Sum All set-ups TRUE - Uint8
3-1* References
3-10 Preset Reference 0.00% All set-ups TRUE -2 Int16
3-11 Jog Speed [Hz] App.Dependent All set-ups TRUE -1 Uint16
3-12 Catch up/slow Down Value 0.00% All set-ups TRUE -2 Int16
3-13 Reference Site [0] Linked to Hand / Auto All set-ups TRUE - Uint8
3-14 Preset Relative Reference 0.00% All set-ups TRUE -2 Int32
3-15 Reference Resource 1 null All set-ups TRUE - Uint8
3-16 Reference Resource 2 null All set-ups TRUE - Uint8
3-17 Reference Resource 3 null All set-ups TRUE - Uint8
3-18 Relative Scaling Reference Resource [0] No function All set-ups TRUE - Uint8
3-19 Jog Speed [RPM] App.Dependent All set-ups TRUE 67 Uint16
3-4* Ramp 1
3-40 Ramp 1 Type [0] Linear All set-ups TRUE - Uint8
3-41 Ramp 1 Ramp up Time App.Dependent All set-ups TRUE -2 Uint32
3-42 Ramp 1 Ramp Down Time App.Dependent All set-ups TRUE -2 Uint32
3-45 Ramp 1 S-ramp Ratio at Accel. Start 50% All set-ups TRUE 0 Uint8
3-46 Ramp 1 S-ramp Ratio at Accel. End 50% All set-ups TRUE 0 Uint8
3-47 Ramp 1 S-ramp Ratio at Decel. Start 50% All set-ups TRUE 0 Uint8
3-48 Ramp 1 S-ramp Ratio at Decel. End 50% All set-ups TRUE 0 Uint8
3-5* Ramp 2
3-50 Ramp 2 Type [0] Linear All set-ups TRUE - Uint8
3-51 Ramp 2 Ramp up Time App.Dependent All set-ups TRUE -2 Uint32
3-52 Ramp 2 Ramp down Time App.Dependent All set-ups TRUE -2 Uint32
3-55 Ramp 2 S-ramp Ratio at Accel. Start 50% All set-ups TRUE 0 Uint8
3-56 Ramp 2 S-ramp Ratio at Accel. End 50% All set-ups TRUE 0 Uint8
3-57 Ramp 2 S-ramp Ratio at Decel. Start 50% All set-ups TRUE 0 Uint8
3-58 Ramp 2 S-ramp Ratio at Decel. End 50% All set-ups TRUE 0 Uint8
3-6* Ramp 3
3-60 Ramp 3 Type [0] Linear All set-ups TRUE - Uint8
3-61 Ramp 3 Ramp up Time App.Dependent All set-ups TRUE -2 Uint32
3-62 Ramp 3 Ramp down Time App.Dependent All set-ups TRUE -2 Uint32
3-65 Ramp 3 S-ramp Ratio at Accel. Start 50% All set-ups TRUE 0 Uint8
3-66 Ramp 3 S-ramp Ratio at Accel. End 50% All set-ups TRUE 0 Uint8
3-67 Ramp 3 S-ramp Ratio at Decel. Start 50% All set-ups TRUE 0 Uint8
3-68 Ramp 3 S-ramp Ratio at Decel. End 50% All set-ups TRUE 0 Uint8
3-7* Ramp 4
3-70 Ramp 4 Type [0] Linear All set-ups TRUE - Uint8
3-71 Ramp 4 Ramp up Time App.Dependent All set-ups TRUE -2 Uint32
3-72 Ramp 4 Ramp Down Time App.Dependent All set-ups TRUE -2 Uint32
3-75 Ramp 4 S-ramp Ratio at Accel. Start 50% All set-ups TRUE 0 Uint8
3-76 Ramp 4 S-ramp Ratio at Accel. End 50% All set-ups TRUE 0 Uint8
3-77 Ramp 4 S-ramp Ratio at Decel. Start 50% All set-ups TRUE 0 Uint8
3-78 Ramp 4 S-ramp Ratio at Decel. End 50% All set-ups TRUE 0 Uint8
Parameter Lists
VLT
®
AutomationDrive Programmming Guide
168 MG33ME02 - VLT
®