Installation and set up
46
Arex™ 400
Connecting Safety Circuit connector
The Safety Circuit connector must always be inserted with properly signals pro-
vided in order to use the laser marker. The absence of such connector blocks the
laser emission.
W
ARNING
W
ARNING
NOTE
See "Appendix B Understanding SLO: Safe Laser Off" on page 83 about the compli-
ance to safety.
It is the customer's responsibility to provide a correct inte
gration of the safety signals
according to applicable regulations.
Do not use the Safety Circuit Muting Device for external devic
es, since this will result in
loss of the safety function of the machine to which this product is installed.
Do not use the Safety Circuit Muting Devic
e except for maintenance oh this product.
Figure 2: Connecting Safety connector