Page 24/27
© 2019 Datalogic S.r.l – All Rights Reserved
Invalid Field Symbol Object ID
Bad Grade required validation
MARVIS License is not enabled
Focal Distance Sensor Unavailable
Focal Distance Sensor Focus Error
Focal Distance Sensor Reference Invalid
Focal Distance Sensor Out Of Range
Focal Distance Sensor Connection Error
Focal Distance Sensor Communication Error
Focal Distance Sensor Invalid Focus Search
Command exceeds memory area
Command Error are not blocking errors which request an acknowledgement from the
PLC: after that any kind of Command Error is reported, the PLC will be able immediately
request a new command to the Laser Marker, which will try to execute it normally.
Protocol Error
A Protocol Error is notified to the PLC when the Laser Marking System is not able to
correctly determinate a single command to execute.
In addition to the single ‘Protocol Error’ notification bit, a whole byte (address 5) of the
Input Assembly Memory Map describes the reason of the error:
Command conflict: more than 1 command bit is set to 1
Unknown command: bit(s) in a reserved area is/are set to 1
Busy: Protocol in Executing state when Command bit is set to 1 (except for STOP command bit)
Critical: Protocol state machine is faulted