TWO-HEAD DIMENSIONING SYSTEM REFERENCE MANUAL
122
5
5.4.2 Tach/Trigger/Transmit (DC3000 User Interface)
Use Tach/Trigger/Transmit to set up the tachometer source and trigger source. A range of
settings are definable based on use of hardware or software sources (see section 4.7).
1. In the menu tree under Modify Settings, select Tach/Trigger/Transmit. The
Tach/Trigger/Transmit window opens.
2. Measure the distance from the photoelectric sensor and the scan line of HEAD1, and
enter this measurement in the Trigger Reference Point text field. Use a box set just
along the photoelectric sensor laser to aid in measuring.
Figure 59: Trigger Reference Point measurement
HEAD 1
X Shift 0.000
Direction of Travel
HEAD 2
Downstream
HEAD 2
X Shift