Technical Features
16 Gryphon™ GFS4400
RS-232 Electrical Connections
Default configuration is RS-232: 9600, 8, N, 1, no handshaking, ACK/NAK disabled.
Figure 1. Output Connection
9-pin connector
1Trigger
Trigger signal input (see Figure 2 and Figure 3 on
next page)
2 TX Transmit Data (output from scanner)
3 RX Receive Data (input to scanner)
4NC Not connected
5GND Ground
6VCC +5Vdc
7 CTS Clear To Send (input to scanner)
8 RTS Request To Send (output from scanner)
9
DIGITAL OUT-
PUT
Output signal (see Figure 1)
c
OUT
9
5
GND
USER INTERFACEGFS4450-9
Vext 14Vdc max
Output Connection
DB9