References RS-232 Parameters
246
Gryphon™ I GFS4400
ACK NAK Options
This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol.
When configured, the reader and/or host sends an “ACK” when it receives data properly, and
sends “NAK” when the data is in error.
Options are:
•Disable
Enable for label transmission — The reader expects an ACK/NAK response from the host
when a label is sent.
Enable for host-command acknowledge — The reader will respond with ACK/NAK
when t
he host sends a command.
Enable for label transmission and host-command acknowledge
ACK Character
This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII
characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host com-
mands conflicts with normal operation of these characters. 8-bit data is not
reco
gnized when the option
Data Bits
has been set as 7 Data Bits.
1. Determine the desired character or value.
2. Use the
ASCII Chart
on the inside back cover of this manual to find the hex equivalent for
the desired character/value.
3. Go to
page 33
and scan ENTER/EXIT PROGRAMMING MODE to enter Program-
ming Mode.
4. Scan the bar code: SELECT ACK CHARACTER SETTING.
5. Scan the appropriate two alphanumeric
characters
from the keypad in
Appendix E, Keypad
,
that represent the desired character/value in step 1 above. The second character will cause
a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
See
Table 26
for some examples of how to set this feature.
Table 26. ACK Character Setting Examples
STEP ACTION EXAMPLES
1 Desired Character/Value
ACK $ @ >
2 Hex equivalent from
ASCII Chart
0x06 0x24 0x40 0x3E
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT ACK CHARACTER SETTING
5
Scan Two Characters from
Appendix E, Keypad
‘0’ and ‘6’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’
6 Scan ENTER/EXIT PROGRAMMING MODE