Enter/Exit Programming Mode Reading Parameters
74
Gryphon™ I GFS4400
Double Read Timeout
Double Read Timeout specifies the minimum time between consecutive good reads of labels of
the same symbology and data. This prevents a double read of the same label. If the unit reads a
label and sees the same label again within the specified timeout, the second read is ignored.
Double Read Timeout does not apply to scan modes that require a trigger pull for each label
read. The timeout can be set within a range of 20 milliseconds to 2,550 milliseconds (2.55
seconds) in 10ms increments.
$CSNDR0A(CR)
Double Read Timeout = 0.1 Second
$CSNDR32(CR)
Double Read Timeout = 0.5 Second
$CSNDR64(CR)
Double Read Timeout = 1 Second
DEFAULT
To specify your own setting, scan the bar code below followed by the appropriate characters
from Appendix E, Keypad. See page 266 in “References” for detailed instructions and examples
for setting this feature.
$CSNDR
Select Double Read Timeout Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL