EasyManua.ls Logo

Datalogic Gryphon I GFS4400 - Manual Trigger Control; Presentation Mode Indication

Datalogic Gryphon I GFS4400
324 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reading Parameters Enter/Exit Programming Mode
Product Reference Guide
83
Presentation Mode Indication
This operation is useful for indicating when the reader is in Automatic/Triggered Object Sense
Operating Mode. If enabled, the blue indicator will blink when Presentation Mode scanning is
active.
DEFAULT
$CSMFL00(CR)
Presentation Mode Indication = Disable
$CSMFL01(CR)
Presentation Mode Indication = Enable
Manual Trigger Control
This feature is available in Serial On Line mode only.
This feature is used to enable/disable manual trigger when the reader is in Serial On Line
reading mode.
Enable: allows a manual trigger push to start
a reading phase.
Disable: (default) locks out the trigger button and does not allow manual triggering to
start a r
eading phase. When disabled, the trigger can still be activated once by pressing and
holding the trigger for 5 seconds to enter Debug Mode.
DEFAULT
$CSOTM00
Manual Trigger Control = Disable
$CSOTM01
Manual Trigger Control = Enable