Enter/Exit Programming Mode Reading Parameters
84
Gryphon™ I GFS4400
Central Code Only
Specifies the ability of the reader to decode labels only when they are close to the center of the
aiming pattern. This allows the reader to accurately target labels when they are placed close
together, such as on a pick sheet.
See Appendix B, Aimer Calibration starting on page 285 for information about setting the
aiming coordinates.
This feature is not compatible with Multiple Labels Reading in a Volume.
DEFAULT
$CSNPM00(CR)
Central Code Only = Disable
$CSNPM01(CR)
Central Code Only = Enable
Illumination Off Time
This feature defines the amount of time illumination is kept OFF after Illumination ON
timeout. When illumination OFF expires, Object Sense is resumed. This configuration is
available in Automatic (Object Sense) only. Range is 0 millisecond to 25.5 milliseconds in 100
millisecond intervals.
$CSNOO
Select Presentation Mode Time Setting
To configure this feature, scan the ENTER/EXIT PROGRAM-
MING MODE bar code above, then the bar code at left fol-
lowed by the digits from the Alphanumeric characters in
Appendix E, Keypad representing your desired charac-
ter(s). End by scanning the ENTER/EXIT bar code again.
DEFAULT
0 milliseconds