Loading...
1D Symbologies Enter/Exit Programming Mode
Product Reference Guide
107
Code 39 Set Length 2
This feature specifies one of the bar code lengths for Code 39 Length Control.
Length 2 is the maximum label length if in Variable Length Mode, or the sec-
ond fixed length if in Fixed Length Mode. Length includes the bar code’s
check, data, and full-ASCII shift characters. The length does not include
start/stop characters.
Table 4 provides examples for setting Length 2. See page 241 for detailed
instructions on setting this feat
ure.
Table 4. Code 39 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 39 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING .MODE
$CC3L2
Select Code 39 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters