RS-232 Parameters
Product Reference Guide
225
Enable Character
Specifies the value of the RS-232 host command used to enable the scanner.
ASCII characters or any hex value from 0 to 0xFF can be selected.
NOTE
Setting to previously defined characters such as XON, XOFF, or host com-
mands conflicts with normal operation of these characters. 8-bit data is
not re
cognized when the option
Stop Bits on page 22
has been set as 7
Data Bits.
To set this feature:
Determine the desired ch
aracter or value.
A setting of 0xFF indicates the Enable
Character is not used (not available).
1. Determine the desired character or value.
2. Use the
ASCII Chart on page 287
on the inside back cover of this manual to
find the hex equivalent for the desired character/value.
3. Go to
page 34
and scan the ENTER/EXIT PROGRAMMING MODE bar code to
enter Programming Mode.
4. Scan the bar code: SELECT ENAB
LE CHA
RACTER SETTING on
page 34
.
5. Scan the appropriate two alphanumeric characters from the keypad in
Appendix D, Keypad
, that represent the desired character/value determined
above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See the table below for examples of how to set
this fe
ature.
Table 8. Enable Character Setting Examples
STEP ACTION EXAMPLES
1 Desired character/value
‘e’ ‘}’ ‘E’
Enable Command
Not Used
2
Hex equivalent from
ASCII
Chart on page 287
0x65 0x7D 0x45 0xFF
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT ENABLE CHARACTER SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘6’ and ‘5’ ‘7’ and ‘D’ ‘4’ and ‘5 ‘F’ and ‘F
6 Scan ENTER/EXIT PROGRAMMING MODE