EasyManua.ls Logo

Datalogic Heron HD3430 - Maxicode; Maxicode Enable; Disable; Maxicode Primary Message Transmission

Datalogic Heron HD3430
310 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Symbology Selection Enter/Exit Programming Mode
Product Reference Guide
213
Maxicode
Maxicode Enable / Disable
Enables/disables ability of reader to decode Maxicode labels.
DEFAULT
$CMXEN00(CR)
Maxicode = Disable
$CMXEN01(CR)
Maxicode = Enable
Maxicode Primary Message Transmission
Enables/disables the transmission of only the Primary Message when the
Secondary Message is not readable.
DEFAULT
$CMXPT00(CR)
Maxicode Primary Message Transmission = Disable
$CMXPT01(CR)
Maxicode Primary Message Transmission = Enable