PUSH-PULL, Overcurrent protection
≥ Uv-2V @ 250 mA
≤ 0.2V
max. 250 mA
< 700 μA
a
PUSH-PULL, Overcurrent protection
≥Uv-2V @ 250 mA
≤ 0.2V
max. 250 mA
< 700 μA
a
> 12 V
< 5 V
2 mA @ 24 Vdc
12 kΩ
a. In the case of a fault (0 V cable open circuit) maximally the leakage current flows in the OSSD cable. The
downstream controller must detect this status as LOW. A FPLC (fail-safe programmable logic controller)
must be able to identify this status.
2 H
2.2
F
a.
In the case of a fault (0 V cable open circuit) maximally the leakage current flows in the OSSD cable. The
downstream controller must detect this status as LOW. A FPLC (fail-safe programmable logic controller)
must be able to identify this status.
2 H
2.2
F
115 s
b
(typical value)
b.
Refer to
"
OSSD test" on page 66
900 ms
b
(typical value)
150 ms
b
(typical value)
300 ms
b
(typical value)
TECHNICAL DATA
118
SAFERY LASER SCANNER
OSSD (SAFETY OUTPUT)
OSSD logic and protection
Output voltage for ON status (HIGH)
Output voltage for OFF status (LOW)
Output current for ON status (HIGH)
Leakage current
Max Load inductance
Max Load capacity
Test pulse width
Test period on single OSSDx
Test pulse shift time between OSSD pairs
Test pulse shift time between OSSDs
OUTPUT (WARNING AND GENERIC)
Output logic and protection
Output voltage for ON status (HIGH)
Output voltage for OFF status (LOW)
Output current for ON status (HIGH)
Leakage current
Max. Load inductance
Max. Load capacity
STATIC INPUT (GENERIC)
Input voltage (HIGH)
Input voltage (LOW)
Input current (HIGH)
Input impedance